U.S. Department of Health & Human Services Divider Arrow National Institutes of Health Divider Arrow NCATS

Details

Stereochemistry ABSOLUTE
Molecular Formula 2C6H8O8.Tc
Molecular Weight 515.1521
Optical Activity UNSPECIFIED
Defined Stereocenters 8 / 8
E/Z Centers 0
Charge 0

SHOW SMILES / InChI
Structure of TECHNETIUM TC-99M GLUCARATE

SMILES

[99Tc+4].O[C@@H]([C@H](O)[C@@H](O)C([O-])=O)[C@H](O)C([O-])=O.O[C@@H]([C@H](O)[C@@H](O)C([O-])=O)[C@H](O)C([O-])=O

InChI

InChIKey=KPEIQXMVJTXIKL-IQOUTWGWSA-J
InChI=1S/2C6H10O8.Tc/c2*7-1(3(9)5(11)12)2(8)4(10)6(13)14;/h2*1-4,7-10H,(H,11,12)(H,13,14);/q;;+4/p-4/t2*1-,2-,3-,4+;/m00./s1/i;;1+1

HIDE SMILES / InChI

Molecular Formula Tc
Molecular Weight 98.9063
Charge 4
Count
Stereochemistry ACHIRAL
Additional Stereochemistry No
Defined Stereocenters 0 / 0
E/Z Centers 0
Optical Activity NONE

Molecular Formula C6H8O8
Molecular Weight 208.1229
Charge -2
Count
Stereochemistry ABSOLUTE
Additional Stereochemistry No
Defined Stereocenters 4 / 4
E/Z Centers 0
Optical Activity UNSPECIFIED

Description
Curator's Comment: description was created based on several sources, including https://www.ncbi.nlm.nih.gov/books/NBK215133/ | https://www.iaea.org/OurWork/ST/NE/NEFW/Technical-Areas/RRS/documents /mo99/WORKINGMATERIALSmo99CM.pdf | https://www.ncbi.nlm.nih.gov/pubmed/27854401

Molybdenum-99 (99Mo, half-life = 66 h) is a parent radionuclide of a diagnostic nuclear isotope. It decays in technetium-99 m (half-life = 6 h), which is used in over 30 million procedures per year around the world. Between 95 and 98 percent of Mo-99 is currently being produced using highly enriched uranium (HEU) targets. Other medical isotopes such as iodine-131 (I-131) and xenon-133 (Xe-133) are by-products of the Mo-99 production process and will be sufficiently available if Mo-99 is available.

Approval Year

Conditions

Conditions

ConditionModalityTargetsHighest PhaseProduct
Diagnostic
OSTEOLITE

Approved Use

Unknown

Launch Date

2.50992001E11
Diagnostic
DRAXIMAGE MDP-10

Approved Use

MDP-25 (Kit for the Preparation of Technetium Tc 99m Medronate) may be used as a bone imaging agent to delineate areas of altered osteogenesis.

Launch Date

2.80972788E11
PubMed

PubMed

TitleDatePubMed
Patents

Patents

Sample Use Guides

In Vivo Use Guide
Unknown
Route of Administration: Unknown
In Vitro Use Guide
Unknown
Substance Class Chemical
Created
by admin
on Fri Dec 15 15:57:39 UTC 2023
Edited
by admin
on Fri Dec 15 15:57:39 UTC 2023
Record UNII
RXZ75FE8AA
Record Status Validated (UNII)
Record Version
  • Download
Name Type Language
TECHNETIUM TC-99M GLUCARATE
Common Name English
D-GLUCARIC ACID, TECHNETIUM-99TC SALT
Systematic Name English
Code System Code Type Description
CAS
149751-64-4
Created by admin on Fri Dec 15 15:57:39 UTC 2023 , Edited by admin on Fri Dec 15 15:57:39 UTC 2023
NON-SPECIFIC STOICHIOMETRY
PUBCHEM
162623760
Created by admin on Fri Dec 15 15:57:39 UTC 2023 , Edited by admin on Fri Dec 15 15:57:39 UTC 2023
PRIMARY
FDA UNII
RXZ75FE8AA
Created by admin on Fri Dec 15 15:57:39 UTC 2023 , Edited by admin on Fri Dec 15 15:57:39 UTC 2023
PRIMARY
Related Record Type Details
PARENT -> SALT/SOLVATE
PARENT -> SALT/SOLVATE
Related Record Type Details
ACTIVE MOIETY